It can be used to measure AC and DC voltage, low-pass filter VFC voltage, low impedance Low Z voltage, AC and DC current, resistance, diode, continuity test , capacitance, frequency, duty cycle, temperature and other parameters, and has data hold, relative value measurement, surge current measurement function, torch function, NCV function, live wire judgment, under-voltage display and automatic shutdown function.
Specifications |
|||
Function |
Range |
615B |
|
DC V |
600mV/6V/60V/600V/1500V |
± (0.5%+7) |
|
AC V |
6V/60V/600V/1000V |
± (1.0%+10) |
|
Low-V(AC) |
6V/60/V/300V |
± (1.0%+10) |
|
DC A |
60A/600A/1000A |
± (4.0%+10) |
|
AC A |
60A/600A/1000A |
± (4.0%+10) |
|
Resistance |
600Ω/6kΩ/60kΩ/600kΩ/6MΩ/20MΩ/60MΩ |
± (1.0%+5) |
|
Capacitance |
1nF/10nF/100nF/1μF/10μF/100μF/1mF/10mF |
± (5.0%+10) |
|
Frequency |
10Hz-10MHz |
± (0.3%+3) |
|
Duty cycle |
10.0%-90.0% |
0.1% |
|
Temperature |
-20°C~1000°C / -4°F~1832°F |
± (2.0%+5) |
Feature |
|
Model |
615B |
Diode & continuity Test |
√ |
Relative value measurement |
√ |
Low battery indication |
√ |
Data Hold |
√ |
NCV (non-contact voltage detection) |
√ |
Auto power off |
√ |
Live wire test |
√ |
Flash light |
√ |
Zeroing |
√ |
Low-Z measurement |
√ |
V.F.C (low pass filter) |
√ |
Inrush current measurement |
√ |
DC current zeroing |
√ |
Operation way |
Auto range |
Max. display |
5999 |
Jaw size |
40mm |
General Information |
|
Model |
615B |
Power Supply |
AAA,1.5Vx2 |
Product color |
Black+ Orange |
Product weight |
313g |
Product size |
230x75x40mm |
Standard accessories |
Test leads, batteries, manual, pouch, temperature probe |